|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Hall Sensor KSY 16 Features * Hall sensor on Cu-leadframe for SMT-technology, MW-6 package * High sensitivity * High temperature range * Small linearity error * Low offset voltage * Low TC of sensitivity resistances * This Hall sensor combines the avantages of nonmagnetic leadframe and SMT capability Typical applications * Rotation and position sensing * Current and power measurement * Magnetic field measurement * Control of brushless DC motors Approx. weight 0.02 g Pin Configuration 1, 4 Hall voltage terminals 3+, 2- Supply current terminals Dimensions in mm Type KSY 16 Marking s16 Ordering Code on request The KSY 16 is an ion-implanted Hall sensor in a monocrystalline GaAs-material, built into an SMT package (MW-6). It is outstanding for a high magnetic sensitivity and low temperature coefficients. The 0.35 x 0.35 mm2 chip is mounted onto a non-magnetic leadframe. The active area is placed approx. 0.45 mm below the surface of the package. Semiconductor Group 1 07.96 KSY 16 Maximum ratings Parameter Operating temperature Storage temperature Supply current Thermal conductivity1) Characteristics (TA = 25 C) Nominal supply current Open-circuit sensitivity Open-circuit Hall voltage I = I1N, B = 0.1 T Ohmic offset voltage I = I1N, B = 0 T Linearity of Hall voltage Symbol Value - 40...+ 150 - 50...+ 160 7 2.2 Unit C C mA mW/K TA Tstg I1 GthC I1N KB0 V20 VR20 5 190...260 95...130 20 mA V/AT mV mV B = 0...0.5 T B = 0...1 T Input resistance Output resistance B=0 T B=0 T Temperature coefficient of the open-circuit Hall voltage I1 = I1N, B = 0.1 T Temperature coefficient of the internal resistance B=0 T Change of offset voltage within the temperature range2) FL FL R10 R20 TCV20 0.2 0.7 900...1200 900...1200 - 0.03...- 0.07 % % %/K TCR10, R20 VR0 0.1...0.18 %/K 2 mV Connection of a Hall sensor with a power source Since the voltage on the component must not exceed 10 V, the connection to the constant current supply should only be done via a short circuit by-pass. The by-pass circuit-breaker shall not be opened before turning on the power source. This is to avoid damage to the Hall sensor due to power peaks. 1) Thermal conductivity chip-ambient when mounted on alumina ceramic 15 mm x 17 mm x 0.7 mm 2) AQL: 0.65 Semiconductor Group 2 |
Price & Availability of KSY16 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |